Return to flip book view

FLEX FABRIC SEAM TAPE SDS - A

Page 1

SAFETY DATA SHEETGET COATEDFLEX FABRIC REINFORCEMENT info@flexrockcoatings.com | 800-808-0414 | FlexRockCoatings.comFLEX FABRIC SEAM TAPEFLEX FABRIC SEAM TAPE

Page 2

Material name: FLEX Fabric Seam Tape / 4EvaSeal Tape 1086 Version #: 01 Issue date: 04-12-2016 SDS US 2 / 7 SAFETY DATA SHEET 1. IdentificationProduct identifier Other means of identification Synonyms Recommended use Recommended restrictions FLEX FABRIC SEAM TAPEFLEX Fabric Seam Tape / 4EvaSeal Gray Tape, Black Tape, Tan Tape, White Tape, Aluminum Tape, Fabric Tape, Double Sided Tape Not available. None known. Manufacturer/Importer/Supplier/Distributor information Manufacturer Hazard symbol None. Signal word None. Hazard statement The mixture does not meet the criteria for classification. Precautionary statement Prevention Observe good industrial hygiene practices. Response Wash hands after handling. Storage Store away from incompatible materials. Disposal Dispose of waste and residues in accordance with local authority requirements. Hazard(s) not otherwise classified (HNOC) None known. Supplemental information None. 3. Composition/information on ingredientsMixtures Company name Address 4Eva Seal 1527 Lyons Street Evanston, IL 60201 United States Telephone General Assistance 800 543-3458 E-mailinfo@chasecorp.com Emergency phone numberChemtrec (US - 24 hrs) 800 424-9300 Chemtrec (INTL - 24 hrs) 703-527-38872. Hazard(s) identificationPhysical hazards Not classified. Health hazards Not classified. Environmental hazards Not classified. OSHA defined hazards Not classified. Label elements

Page 3

Material name: FLEX Fabric Seam Tape / 4EvaSeal Tape 1086 Version #: 01 Issue date: 04-12-2016 SDS US 3 / 7 Chemical name Common name and synonyms CAS number % Talc (powder) 14807-96-6 10 - < 20 Other components below reportable levels 80 - < 90 *Designates that a specific chemical identity and/or percentage of composition has been withheld as a trade secret.4. First-aid measuresInhalation Move to fresh air. Call a physician if symptoms develop or persist. Skin contact Wash off with soap and water. Get medical attention if irritation develops and persists. Eye contact Rinse with water. Get medical attention if irritation develops and persists. Ingestion Rinse mouth. Get medical attention if symptoms occur. Most important symptoms/effects, acute and delayed Indication of immediate medical attention and special treatment needed Direct contact with eyes may cause temporary irritation. Treat symptomatically. General information Ensure that medical personnel are aware of the material(s) involved, and take precautions to protect themselves. 5. Fire-fighting measuresSuitable extinguishing media Water fog. Foam. Dry chemical powder. Carbon dioxide (CO2). Unsuitable extinguishing media Specific hazards arising from the chemical Special protective equipment and precautions for firefighters Fire-fighting equipment/instructions Do not use water jet as an extinguisher, as this will spread the fire. During fire, gases hazardous to health may be formed. Self-contained breathing apparatus and full protective clothing must be worn in case of fire. Use water spray to cool unopened containers. Specific methods Use standard firefighting procedures and consider the hazards of other involved materials. General fire hazards No unusual fire or explosion hazards noted. 6. Accidental release measuresPersonal precautions, protective equipment and emergency procedures Methods and materials for containment and cleaning up Keep unnecessary personnel away. For personal protection, see section 8 of the SDS. Stop the flow of material, if this is without risk. Following product recovery, flush area with water. For waste disposal, see section 13 of the SDS. Environmental precautions Avoid discharge into drains, water courses or onto the ground. 7. Handling and storagePrecautions for safe handling Avoid prolonged exposure. Observe good industrial hygiene practices. Conditions for safe storage, including any incompatibilities Store in original tightly closed container. Store away from incompatible materials (see Section 10 of the SDS). 8. Exposure controls/personal protectionOccupational exposure limits US. OSHA Table Z-3 (29 CFR 1910.1000) Components Type Value Form Talc (powder) (CAS 14807-96-6) TWA 0.3 mg/m3 Total dust. 0.1 mg/m3 Respirable. 20 mppcf 2.4 mppcf Respirable.

Page 4

Material name: FLEX Fabric Seam Tape / 4EvaSeal Tape 1086 Version #: 01 Issue date: 04-12-2016 SDS US 4 / 7 US. ACGIH Threshold Limit Values Components Type Value Form Talc (powder) (CAS 14807-96-6) TWA 2 mg/m3 Respirable fraction. US. NIOSH: Pocket Guide to Chemical Hazards Components Type Value Form Talc (powder) (CAS 14807-96-6) TWA 2 mg/m3 Respirable. Biological limit values No biological exposure limits noted for the ingredient(s). Appropriate engineering controls Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Individual protection measures, such as personal protective equipment Eye/face protection Wear safety glasses with side shields (or goggles). Skin protection Hand protection Wear appropriate chemical resistant gloves. Other Wear suitable protective clothing. Respiratory protection In case of insufficient ventilation, wear suitable respiratory equipment. Thermal hazards Wear appropriate thermal protective clothing, when necessary. General hygiene considerations Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove contaminants. 9. Physical and chemical propertiesAppearance Physical state Solid. Form Solid. Roll. or Sheets. Color Various film colors, gray adhesive Odor Slight. Odor threshold Not available. pH Not available. Melting point/freezing point Not available. Initial boiling point and boiling range Not available. Flash point > 428.0 °F (> 220.0 °C)Evaporation rate Not available. Flammability (solid, gas) Not available. Upper/lower flammability or explosive limits Flammability limit - lower (%) Flammability limit - upper (%) Not available. Not available. Explosive limit - lower (%) Not available. Explosive limit - upper (%) Not available. Vapor pressure Not available. Vapor density Not available. Relative density Not available. Solubility(ies) Solubility (water) Not available. Partition coefficient (n-octanol/water) Not available. Auto-ignition temperature > 842 °F (> 450 °C)

Page 5

Material name: FLEX Fabric Seam Tape 4EvaSeal Tape 1086 Version #: 01 Issue date: 04-12-2016 SDS US 5 / 7 Decomposition temperature Not available. Viscosity Not available. Other information Density 1.04 g/cm3 estimated Specific gravity 1.04 estimated 10. Stability and reactivityReactivity The product is stable and non-reactive under normal conditions of use, storage and transport. Chemical stability Material is stable under normal conditions. Possibility of hazardous reactions No dangerous reaction known under conditions of normal use. Conditions to avoid Avoid temperatures exceeding the flash point. Contact with incompatible materials. Incompatible materials Strong oxidizing agents. Hazardous decomposition products No hazardous decomposition products are known. 11. Toxicological informationInformation on likely routes of exposure Ingestion Expected to be a low ingestion hazard. Inhalation Prolonged inhalation may be harmful. Skin contact No adverse effects due to skin contact are expected. Eye contact Direct contact with eyes may cause temporary irritation. Symptoms related to the physical, chemical and toxicological characteristics Direct contact with eyes may cause temporary irritation. Information on toxicological effects Acute toxicity Not available. Skin corrosion/irritation Prolonged skin contact may cause temporary irritation. Serious eye damage/eye irritation Respiratory or skin sensitization Direct contact with eyes may cause temporary irritation. Respiratory sensitization Not available. Skin sensitization This product is not expected to cause skin sensitization. Germ cell mutagenicity No data available to indicate product or any components present at greater than 0.1% are mutagenic or genotoxic. Carcinogenicity This product is not considered to be a carcinogen by IARC, ACGIH, NTP, or OSHA. IARC Monographs. Overall Evaluation of Carcinogenicity Talc (powder) (CAS 14807-96-6) 2B Possibly carcinogenic to humans. 3 Not classifiable as to carcinogenicity to humans. OSHA Specifically Regulated Substances (29 CFR 1910.1001-1050) Not listed. Reproductive toxicity This product is not expected to cause reproductive or developmental effects. Specific target organ toxicity - single exposure Specific target organ toxicity - repeated exposure Not classified. Not classified. Aspiration hazard Not available. Chronic effects Prolonged inhalation may be harmful. 12. Ecological informationEcotoxicity The product is not classified as environmentally hazardous. However, this does not exclude the possibility that large or frequent spills can have a harmful or damaging effect on the environment. Persistence and degradability No data is available on the degradability of this product. Bioaccumulative potential Not available.

Page 6

Material name: 4EvaSeal Tape 1086 Version #: 01 Issue date: 04-12-2016 SDS US 6 / 7 Mobility in soil No data available. Other adverse effects No other adverse environmental effects (e.g. ozone depletion, photochemical ozone creation potential, endocrine disruption, global warming potential) are expected from this component. 13. Disposal considerationsDisposal instructions Collect and reclaim or dispose in sealed containers at licensed waste disposal site. Local disposal regulations Dispose in accordance with all applicable regulations. Hazardous waste code The waste code should be assigned in discussion between the user, the producer and the waste disposal company. Waste from residues / unused products Dispose of in accordance with local regulations. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe manner (see: Disposal instructions). Contaminated packaging Empty containers should be taken to an approved waste handling site for recycling or disposal. Since emptied containers may retain product residue, follow label warnings even after container is emptied. 14. Transport informationDOT Not regulated as dangerous goods. IATA Not regulated as dangerous goods. IMDG Not regulated as dangerous goods. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code 15. Regulatory informationNot applicable. US federal regulations All components are on the U.S. EPA TSCA Inventory List. This product is not known to be a "Hazardous Chemical" as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200. TSCA Section 12(b) Export Notification (40 CFR 707, Subpt. D) Not regulated. CERCLA Hazardous Substance List (40 CFR 302.4) Not listed. SARA 304 Emergency release notification Not regulated. OSHA Specifically Regulated Substances (29 CFR 1910.1001-1050) Not listed. Superfund Amendments and Reauthorization Act of 1986 (SARA) Hazard categories Immediate Hazard - No Delayed Hazard - No Fire Hazard - No Pressure Hazard - No Reactivity Hazard - No SARA 302 Extremely hazardous substance Not listed. SARA 311/312 Hazardous No chemical SARA 313 (TRI reporting) Not regulated. Other federal regulations Clean Air Act (CAA) Section 112 Hazardous Air Pollutants (HAPs) List Not regulated. Clean Air Act (CAA) Section 112(r) Accidental Release Prevention (40 CFR 68.130) Not regulated. Safe Drinking Water Act (SDWA) Not regulated.

Page 7

Material name: FLEX Fabric Seam Tape / 4EvaSeal Tape 1086 Version #: 01 Issue date: 04-12-2016 SDS US 7 / 7 US state regulations US. Massachusetts RTK - Substance List Talc (powder) (CAS 14807-96-6) US. New Jersey Worker and Community Right-to-Know Act Talc (powder) (CAS 14807-96-6) US. Pennsylvania Worker and Community Right-to-Know Law Talc (powder) (CAS 14807-96-6) US. Rhode Island RTK Not regulated. US. California Proposition 65 Titanium Dioxide is listed due to its respirable nature in powder form. As supplied and applied the titanium dioxide is bound within the product matrix and is not expected to be in a respirable form. WARNING: This product contains a chemical known to the State of California to cause cancer. US - California Proposition 65 - CRT: Listed date/Carcinogenic substance TITANIUM DIOXIDE (CAS 13463-67-7) Listed: September 2, 2011 International Inventories Country(s) or region Inventory name On inventory (yes/no)* Australia Australian Inventory of Chemical Substances (AICS) Canada Domestic Substances List (DSL) Canada Non-Domestic Substances List (NDSL) China Inventory of Existing Chemical Substances in China (IECSC) Europe European Inventory of Existing Commercial Chemical Substances (EINECS) Europe European List of Notified Chemical Substances (ELINCS) Japan Inventory of Existing and New Chemical Substances (ENCS) Korea Existing Chemicals List (ECL) New Zealand New Zealand Inventory Philippines Philippine Inventory of Chemicals and Chemical Substances (PICCS) United States & Puerto Rico Toxic Substances Control Act (TSCA) Inventory *A "Yes" indicates that all components of this product comply with the inventory requirements administered by the governing country(s)No No Yes Yes No No No No Yes Yes Yes A "No" indicates that one or more components of the product are not listed or exempt from listing on the inventory administered by the governing country(s).16. Other information, including date of preparation or last revisionIssue date 05-20-2015Version # 01HMIS® ratings Health: 0 Flammability: 0 Physical hazard: 0 NFPA ratings Health: 0 Flammability: 0 Instability: 0 Disclaimer The information offered in this data sheet is designed only as guidance for the safe use, storage and handling of the product. This information is correct to the best of our knowledge and belief at the date of publication, however, no guarantee is made to its accuracy. This information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any other process. This material is intended for industrial use only. No warranty, expressed or implied is made.